OPERATING INSTRUCTIONS SUMMARY FOR A LPG SYSTEM
1. Close tank valve immediately in any emergency.
2. Be sure all appliance valves are closed before opening tank valve.
3. Always apply lit match or other flame to burner before opening valve.
4. Close tank valve whenever appliance is not in use.
5. Test system for leakage at least twice a month and after any emergency in accordance with the
following procedure:
WITH APPLIANCE VALVES CLOSED AND WITH TANK VALVE OPEN, NOTE
PRESSURE ON GAUGE. CLOSE CYLINDER VALVE. IF THE PRESSURE DROPS,
AS INDICATED ON THE GAUGE, THIS TELLS YOU THERE IS A LEAK IN THE
SYSTEM. LOCATE LEAKAGE BY APPLICATION OF LIQUID DETERGENT OR SOAP
AND WATER SOLUTION TO ALL CONNECTIONS. AFTER LEAK HAS BEEN
REPAIRED, RECHECK SYSTEM BY REPEATING THIS ABOVE TEST. IF LEAK
CANNOT BE REPAIRED, CLOSE TANK VALVE IMMEDIATELY AND DO NOT USE
THIS SYSTEM. REMEMBER LPG IS HEAVIER THAN AIR AND IF ALLOWED TO
REACH BILGES, MACHINERY SPACE OR OTHER ENCLOSED SPACES, IT CAN BE
EXTREMELY DANGEROUS.
6. It is always a good idea to have an approved ABC type fire extinguisher in the galley area.
LPG STOVE WITH IGNITER
TO LIGHT TOP BURNERS WITH SAFETY SYSTEM
1. Push in knobs and turn to “IGN” (Ignite) position.
2. Hold knob in and press the “BURNER IGNITE” button.
3. Hold knob in for 5 to 10 seconds until the thermocouple is hot. This will activate the safety magnet.
4. Release knob and set to desired setting. If the flame does not stay on, the thermocouple is not hot
enough. (Repeat Steps 1-3).
SPARK FROM THE ELECTRODE HAS TO CUT ACROSS THE GAS TO IGNITE
READILY. IF THE SPARK IS JUMPING BELOW THE BURNER PORTS MAKE SURE
THE POINT OF THE ELECTRODE IS CLEAN SO THAT THE SPARKS WILL JUMP
ABOVE THE PORTS.
TO LIGHT OVEN PILOT AND OVEN BURNER WITH SAFETY SYSTEM
1. Ignite the right top burner for 1 minute. This will enable the air in the system to be bled.
2. Turn the thermostat knob from the "OFF" to the “PILOT" position.
3. With the knob pushed-in, light the oven pilot with a match or a lighter.
4. After the pilot is lit keep the knob pushed-in for 10 to 15 seconds.
5. Release knob. Now set the thermostat knob to desired setting.