Page 2

PAT 2000i Portable Appliance Tester7A.C. FLASH TEST1.5KV Class 13.0KV Class 2Note:1. Press # to apply Flash T

Page 3 - TABLE OF CONTENTS

PAT 2000i Portable Appliance Tester8240V APPLIANCESEARTH BOND TESTINSULATION TEST 500V DC(Probe not neededfor

Page 4

Use of the PAT2000i is straight forward. Plug the tester into a suitable outlet and followthe instructions on the LCD display. Variations of the stand

Page 5

The IEE recommends that if testing the protective earth of an appliance results in amarginal fail, then the appliance should be retested taking into a

Page 6

The IEE recommends that flash testing is not required for in service equipment.LOAD TESTBefore switching full power on to an appliance the load test i

Page 7

• Ensure that the earth clip of the bonded earth test cable is securely attached to theappliance. A poor connection may introduce arcing of the contac

Page 8

a selection has been made and it should action the request. NOTE: no action will followunless the hash (enter) key has been pressed. PROCEDURESTEP 1Co

Page 9

manual and automatic test modes. See the IEE publication “CODE OF PRACTICEFOR IN SERVICE INSPECTION AND TESTING OF ELECTRICAL EQUIPMENT” forfurther in

Page 10 - Portable Appliance Tester

5 Insulation test, pass limit0 = Omit insulation test1 = 2 MΩ2 = 4 MΩ3 = 7 MΩ4 = 1 MΩ5 = 0.5 MΩ6 Flash test voltage and pass limit selection0 = Omit F

Page 11

10 Polarity Selection - Full Test Repeat Selection0 = Polarity test excluded1 = Polarity test included2 = Polarity test excluded and repeat full test3

Page 12

NOTICEData may be lost or altered in virtually any electronicmemory under certain circumstances. Therefore SeawardElectronic assumes no responsibility

Page 13

8 1 = 0.75mA leakage pass level2 = 3.50mA leakage pass level3 = 9.90mA leakage pass level9 0 = no repeat test1 = repeat test10 spare, but must be 1Pro

Page 14

Pressing the N key will cyclically present the option of Class I or Class ll testing Pressthe Y key to accept the displayed option. If Class I is sele

Page 15

Pressing the N key cyclically presents all values. Pressing the Y key accepts an areaand then prompts:EARTH LEAD LENGTHIS 1.0 / 1.5 / 2.0 / 2.5 / 3.0

Page 16

RANGE LIMITSUpper and lower limits have been set for each range; readings above the upper levelare held at the upper level preceded by ‘>’. Reading

Page 17

By depressing the # key the display will move through each line of the test results,holding the key down will cause the display to move rapidly throug

Page 18

NOTE: P = Pass test.S = Skip, test not performed.F = Fail test.T = Terminate test if load or leakage pretest fail.A = Aborted test by user.$ = Alphan

Page 19

MAINTENANCEThe PAT2000i is a rugged quality instrument, however care should be taken, failure todo so will reduce the instruments life and hinder its

Page 20

Flash Test.Measuring Range: 0.3 - 6mAAccuracy: +8% +60uATest Voltage: 1.5KVrms for Class I operation3.0KVrms for Class ll operationPass Range: 3, 5mA

Page 21

Appendix APROTECTIVE EARTH THRESHOLDSSTANDARDRESISTANCE THRESHOLDBS3456 Household electrical Appliances (0.1 +R)ΩBS EN 60335 BS 3456 Clause 27.

Page 22

Appendix C:EARTH LEAKAGE LIMITSSTANDARD Class I Class llHand held / StationaryportableBS3456 Household Electrical 0.75 mA 0 75mA or 0.25mA(2)Applianc

Page 23

TABLE OF CONTENTSCONNECTORS AND OPERATIONAL INTERFACEBATTERYBattery ChargingBattery DisposalSAFETYInstructionsGetting StartedFEATURESDescriptionLayout

Page 24

THEINTERESTOF SAFETYTHlS INSTRUMENT SHOULD ONLYBE USED BY COMPETENTSUITABLY TRAINED PERSONNEL AFTER DUE CONSIDERATlONOF ANY HAZARD INVOLVEDSAFETYRead

Page 25

FEATURESDESCRIPTIONThe PAT2000i is one of the most advanced portable appliance testers available,performing nine functions and providing a comprehensi

Page 26

LAYOUTThe PAT2000i is contained in a robust polyethylene moulded case with an integralcarrying handle and separate keypad. Power supplies, 230V/110V s

Page 27

PAT 2000i Portable Appliance Tester4110V APPLIANCESIEC LEAD TESTEARTH SCREEN TESTFOR IT EQUIPMENTPAT 2000i Bo

Page 28

PAT 2000i Portable Appliance Tester5110V APPLIANCESEARTH BOND TESTINSULATION TEST 500V DC(Probe not neededfor

Page 29

PAT 2000i Portable Appliance Tester6A.C. FLASH TEST1.5KV Class 13.0KV Class 2Note:1. Press # to apply Flash T